Product overview:
LC35D01--Liquid Level Controller has three different versions of 12V/24V/220V. It uses high-quality components, advanced welding processes, and installed with threaded holes. The switch of related equipment can be automatically controlled according to the preset liquid level to achieve intelligent management. Customized solution level alarm thresholds according to the needs of user needs to meet the needs of different application scenarios and achieve control liquid levels. The work is stable, safe, and reliable. It is commonly used for household water supply, high water tower, large dams, open -air swimming pools and other scenarios.
LC35D01 Automatic water level control:
Power supply voltage: DC12V/DC24V/AC85-265V(220V Version);
Standby current 11MA(12V)
Working current 80MA(12Vīŧ
Shell material: ABS;
Environmental temperature: -20 â ~+45 â
Work altitude: ≤2000 meters;
Installation method: Screw hole installation;
Size: 80mm*50*31mm
Weight: 86 grams.
Maximum load: 30A /250VAC,30A/120VAC,30A/30VDC
Probe: Recommended LCCAB01 stainless steel probe
NOTE: LCCAB01 water level sensor probe must be purchased separately
LCCAB01 2/5/10 meters 304 stainless steel level probe
Probe:
Probe material: waterproof 304 stainless steel
Probe size: diameter 8MM, length 40MM
Wire:
Conductor material: oxygen-free copper wire
Conductor wire diameter: 0.5 square (20AWG)
Insulation material: high and low temperature resistant silicone
Temperature resistance: -60-200â
Wire color: yellow, green, blue
Wire length: 2/5/10 meters optional
Weight: 85g(2M Probe 3PCS ) ,145g(5M Probe 3PCS ) 248g(10M Probe 3PCS )
Working principle:
The water level rises: When the water level is lower than the ''Low level'', the water pump starts to supply water to the water tower; when the water level is higher than the ''High level'', the water pump stops supplying water.
Water level reduction: When the water level is lower than the ''High level'', the water pump does not work and the water level continues to decrease. When the water level is lower than the ''Low water level'', the water pump starts to supply water to the water tower.