News: 2 Channel Multifunction Delay Timer Module Delay Relay Controller Motor Reverse Cycle Loop Timers KC22B02



Typical applications





1 Motor reversing control circuit,Power supply is DC 5V 12V ,Wiring diagram below. ''LOAD'' may be DC 1-110V OR 85-265V AC/DC Motor





 




2 Live wire and Netural wire control circuit,Power supply is DC 5V 12V ,Wiring diagram below. ''LOAD'' may be AC 85-265V equipment




 



 


 



 


 









Product Name:





DC 5V 12V 2 Channel Multifunction Delay Timer Module Delay Relay Controller Motor Reverse Cycle Loop Timers


 






Package inlcuded:


 


1 PCS DC 5V 12V 2 channel multi-function delay relay board








 








 













Description:







DC 5V 12V 2 channels 0-9999 seconds multi-function delay relay board




Nine kinds of functions can be switched




Products can set the delay time and Function.After setting up, power-up setting value is previous setting delay time and Function as we set last time (power-down memory function);




Size: 75mm × 35mm x 20mm




Weight : 35g




Relay maximum load capacity: DC 1-110V/6A; AC 85-250V/5A














User Manua:


 




Noun resolved:






COM : Common terminal




 




NO: Normal open


 




NC: Normally Close


 




Relay close: COM connect NO,COM disconnect NC


 




Relay open : COM disconnect NO,COM connect NC


 






Function mode :







 




F1 After power on. Relay 1 close,relay 2 open, delay time is T1. Then relay 1 open,relay 2 is close. Delay time is T2.Relay 1 close, relay 2 open, delay time is T1.Such repeated cycles of action...(for Motor reversing)





 




F2 After power on.Relay 1 close, relay 2 close, delay time is T1. Then relay 1 open, relay 2 is open. Delay time is T2 . Relay 1 close , relay 2 close, delay time is T1. Such repeated cycles of action...





 




F3 After power on . Relay 1 close , delay time is T1. Then relay 1 open , Delay time is T2 . Relay 1 close,delay time is T1. Such repeated cycles of action... ,Relay 2 never work .





 
















F4





After power on . Relay 2 open , delay time is T1. Then relay 2 close, Delay time is T2 . Relay 2 close , delay time is T1. Such repeated cycles of action... ,Relay 1 never work .




 




 




F5 After power on . Relay1 and relay 2 close, delay time is T1.Relay1 and relay 2 open (control Live wire and netural wire)





 












F6





After power on . Relay 1 close , delay time is T1. Then relay 1 open,Relay 2 never work .




 




















F7





After power on . Relay 2 no action, delay time is T1. Then relay 2 close, Relay 1 never work .




 




F8 After power on. Relay 1 and Relay 2 both close, delay time is T1. Then relay 1 open,Delay time is T2, relay 2 open.





 












F9





After power on . Relay 1 and Relay 2 both open , delay time is T1. Then relay 1 close, Delay time is T2, relay 2 close.




 




















Function Mode Switch:


 




Keep pressing K1, press K2 to switch Function mode




 




F5 F6 F7 mode has only 1 delay time counter (T1), the other mode has two delay time counters (T1 T2); Keep pressing K1 ,press K3, switch T1 T2 counter .




 






Adjustment delay time :




 




Press K2, switching 4 bits of delay time counter(0000~9999S),the selected bit flash , press K3 to adjusted counter . Repeat to switch the rest bits .


 




After switching all bits ,then press K2 exit adjustable delay mode; or press K1, exit adjustable delay mode; or wait 10 seconds exit adjustment mode




 




Display way :




 




Keep pressing the K3 for 5 seconds , the digital display Turn off. Keep pressing K3 5 second more (or re-power), the digital display Turn on .


 




F5 F6 F7 F8 F9 mode, the delay counter is completed, digital display Turn off, enter a low-power mode, press K1, exit the low-power mode






 


payment