Product Name:DC 5V 7.5V 9V 2Channel RS232 Relay Board Remote Control USB PC UART COM Serial Ports
Typial application :
Communication protocol: UART protocol communication, baud rate 9600kpbs, 8 data bits, one stop bit, no parity. Each data frame contains eight bytes. Two-way data transmission.
Weight : 45g
1.Reading status(reading the satus of the relay (on/off))
Channel 1 :55 56 00 00 00 01 00 AC
Channel 2 :55 56 00 00 00 02 00 AD
Channel 3 :55 56 00 00 00 03 00 AE
Channel 4 :55 56 00 00 00 04 00 AF
2.Relay open(issue this command ,Relay open , COM connect to NO )
Channel 1 :55 56 00 00 00 01 01 AD
Channel 2 :55 56 00 00 00 02 01 AE
Channel 3 :55 56 00 00 00 03 01 AF
Channel 4 :55 56 00 00 00 04 01 B0
3.Relayclose (issue this command ,Relay close , COM disconnect NO , and COM connect to NC )
Channel 1 :55 56 00 00 00 01 02 AE
Channel 2 :55 56 00 00 00 02 02 AF
Channel 3 :55 56 00 00 00 03 02 B0
Channel 4 :55 56 00 00 00 04 02 B1
4.Relay toggle(Relay statusreversal,if COM connect to NO,this commands willDisconnectCOM to NO and Reverse COM connect to NC,and vice versa)
Channel 1 :55 56 00 00 00 01 03 AF
Channel 2 :55 56 00 00 00 02 03 B0
Channel 3 :55 56 00 00 00 03 03 B1
Channel 4 :55 56 00 00 00 04 03 B2
5.Relay momentary(Relay COM connect to NO,disconnect after 200MS )
Channel 1 :55 56 00 00 00 01 04 B0
Channel 2 :55 56 00 00 00 02 04 B1
Channel 3 :55 56 00 00 00 03 04 B2
Channel 4 :55 56 00 00 00 04 04 B3
6.Relay Interlock
Channel 1 :55 56 00 00 00 01 05 B1
Channel 2 :55 56 00 00 00 02 05 B2
Channel 3 :55 56 00 00 00 03 05 B3
Channel 4 :55 56 00 00 00 04 05 B4
Once issue a command, will have a return fame , 7th byte of return fame mean the satus of realy .
1.Return relay open(return this command,mean COM connect to NO )
Channel 1 :33 3C 00 00 00 01 01 71
Channel 2 :33 3C 00 00 00 02 01 72
Channel 3 :33 3C 00 00 00 03 01 73
Channel 4 :33 3C 00 00 00 04 01 74
2.Return relay close(return this command,mean COM disconnect NO , and COM connect to NC )
Channel 1 :33 3C 00 00 00 01 02 72
Channel 2 :33 3C 00 00 00 02 02 73
Channel 3 :33 3C 00 00 00 03 02 74
Channel 4 :33 3C 00 00 00 04 02 75
Remote control, remote measurement system;
Wireless meter;
Access control ;
Identification system;
Data collection;
IT household appliance;
Intelligence household appliance;
Baby monitoring system;
* Delivery Time.
We need 1-2 days to process your order before shipping.There are two shipping methoed. Fast Delivery: The delivery time for US, European countries the delivery will take 3-5 days.Slow Delivery: The delivery time for US, European countries the delivery will take 10-15 days.
* Tracking information.
After we ship package, customer receive automatic email with tracking details.
* Lost Package Policy.
If a package did not arrive in 4 weeks after the shipping date, then this package is treated as Lost. In this case a new package will be shipped to the customer provided we are able to give the same items as those purchased by the customer. If we are not able to provide the same items to substitute the lost ones we will either propose to the customer similar items or refund their cost as it will be mutually agree with the customer. If one or more items neither the same nor similar are available to be shipped, the customer can request to cancel the order entirely, thus the total cost of the order including shipping and handling cost will be fully refunded.